## Description

Updates best practices in the documentation. Include more information on
how to get a camera stream into a driver dashboard.

## Meta

Merge checklist:
- [x] Pull Request title is [short, imperative
summary](https://cbea.ms/git-commit/) of proposed changes
- [x] The description documents the _what_ and _why_
- [x] If this PR changes behavior or adds a feature, user documentation
is updated
- [x] If this PR touches photon-serde, all messages have been
regenerated and hashes have not changed unexpectedly
- [x] If this PR touches configuration, this is backwards compatible
with settings back to v2024.3.1
- [x] If this PR touches pipeline settings or anything related to data
exchange, the frontend typing is updated
- [x] If this PR addresses a bug, a regression test for it is added
2025-04-14 22:05:54 +00:00

3.0 KiB

Best Practices For Competition

Before Competition

  • Ensure you have spares of the relevant electronics if you can afford it (switch, coprocessor, cameras, etc.).
  • Stay on the latest version of PhotonVision until you have tested your full robot system to be functional.
  • Some time before the competition, lock down the version you are using and do not upgrade unless you encounter a critical bug.
  • Have a copy of the installation image for the version you are using on your programming laptop, in case re-imaging (without internet) is needed.
  • Extensively test at your home setup. Practice tuning from scratch under different lighting conditions.
  • Confirm you have followed all the recommendations under the {ref}Networking<docs/quick-start/networking:Networking> documentation (network switch and static IP).
  • Only use high quality ethernet cables that have been rigorously tested.

Camera Streaming

  • All camera streams are published under the NetworkTables table CameraPublisher.
  • The only subtable under CameraPublisher that will work for viewing a driver mode camera stream is the one that contains Output in the name.
  • To view a camera stream in a dashboard, drag the correct subtable from the NetworkTables tree into your dashboard.
  • Use the latest driver dashboard recommended by WPILib on your driver station laptop.

During the Competition

  • Use the field calibration time given at the start of the event:
    • Bring your robot to the field at the allotted time.
    • Make sure the field has match-accurate lighting conditions active.
    • Turn on your robot and pull up the dashboard on your driver station.
    • Point your robot at the targets and ensure you get a consistent tracking (you hold one targets consistently, the ceiling lights aren't detected, etc.).
    • If you have problems with your pipeline, retune the pipeline following the {ref}camera tuning <docs/pipelines/input:Camera Tuning / Input> documentation.
    • Move the robot close, far, angled, and around the field to ensure no extra targets are found.
    • Monitor camera feeds during a practice match to ensure everything is working correctly.
  • After field calibration, use the "Export Settings" button in the "Settings" page to create a backup.
    • Do this for each coprocessor on your robot that runs PhotonVision, and name your exports with meaningful names.
    • This will contain camera information/calibration, pipeline information, network settings, etc.
    • In the event of software/hardware failures (IE lost SD Card, broken device), you can then use the "Import Settings" button and select "All Settings" to restore your settings.
    • This effectively works as a snapshot of your PhotonVision data that can be restored at any point.
  • Before every match:
    • Check the ethernet and USB connectors are seated fully.
    • Close streaming dashboards when you don't need them to reduce bandwidth.
  • Stream at as low of a resolution as possible while still detecting AprilTags to stay within field bandwidth limits.