@@ -60,6 +60,21 @@ TEST(RoboRioSimTest, SetVin) {
EXPECT_EQ(kTestCurrent, RobotController::GetInputCurrent());
}
TEST(RoboRioSimTest, SetBrownout) {
RoboRioSim::ResetData();
DoubleCallback voltageCallback;
auto voltageCb = RoboRioSim::RegisterBrownoutVoltageCallback(
voltageCallback.GetCallback(), false);
constexpr double kTestVoltage = 1.91;
RoboRioSim::SetBrownoutVoltage(units::volt_t{kTestVoltage});
EXPECT_TRUE(voltageCallback.WasTriggered());
EXPECT_EQ(kTestVoltage, voltageCallback.GetLastValue());
EXPECT_EQ(kTestVoltage, RoboRioSim::GetBrownoutVoltage().to<double>());
EXPECT_EQ(kTestVoltage, RobotController::GetBrownoutVoltage().to<double>());
}
TEST(RoboRioSimTest, Set6V) {
RoboRioSim::ResetData();