[hal] Convert DutyCycle Raw output to be a high time measurement (#4466)
The existing raw time has an issue where it jumps around, as in the FPGA if the frequency is not a multiple or divisor of 25 Mhz it jumps around by 1 every second. While waiting on an FPGA change, update the API to make raw output give nanoseconds rather then a scaled value. This does a longer read cycle to get the correct value, but in the future if a fast FPGA function is added this can be easily changed.
This commit is contained in:
@@ -74,15 +74,15 @@ Java_edu_wpi_first_hal_DutyCycleJNI_getOutput
|
||||
|
||||
/*
|
||||
* Class: edu_wpi_first_hal_DutyCycleJNI
|
||||
* Method: getOutputRaw
|
||||
* Method: getHighTime
|
||||
* Signature: (I)I
|
||||
*/
|
||||
JNIEXPORT jint JNICALL
|
||||
Java_edu_wpi_first_hal_DutyCycleJNI_getOutputRaw
|
||||
Java_edu_wpi_first_hal_DutyCycleJNI_getHighTime
|
||||
(JNIEnv* env, jclass, jint handle)
|
||||
{
|
||||
int32_t status = 0;
|
||||
auto retVal = HAL_GetDutyCycleOutputRaw(
|
||||
auto retVal = HAL_GetDutyCycleHighTime(
|
||||
static_cast<HAL_DutyCycleHandle>(handle), &status);
|
||||
CheckStatus(env, status);
|
||||
return retVal;
|
||||
|
||||