mirror of
https://github.com/wpilibsuite/allwpilib
synced 2026-06-29 02:21:44 +00:00
[hal, wpilib] Incorporate pneumatic control type into wpilibc/j (#3728)
This commit is contained in:
@@ -64,7 +64,8 @@ HAL_REVPHHandle HAL_InitializeREVPH(int32_t module,
|
||||
|
||||
SimREVPHData[module].initialized = true;
|
||||
// Enable closed loop
|
||||
SimREVPHData[module].closedLoopEnabled = true;
|
||||
SimREVPHData[module].compressorConfigType =
|
||||
HAL_REVPHCompressorConfigType_kDigital;
|
||||
|
||||
return handle;
|
||||
}
|
||||
@@ -97,26 +98,73 @@ HAL_Bool HAL_GetREVPHCompressor(HAL_REVPHHandle handle, int32_t* status) {
|
||||
return SimREVPHData[pcm->module].compressorOn;
|
||||
}
|
||||
|
||||
void HAL_SetREVPHClosedLoopControl(HAL_REVPHHandle handle, HAL_Bool enabled,
|
||||
int32_t* status) {
|
||||
void HAL_SetREVPHCompressorConfig(HAL_REVPHHandle handle,
|
||||
const HAL_REVPHCompressorConfig* config,
|
||||
int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return;
|
||||
}
|
||||
|
||||
SimREVPHData[pcm->module].closedLoopEnabled = enabled;
|
||||
// TODO
|
||||
// SimREVPHData[pcm->module].compressorConfigType = config.
|
||||
}
|
||||
|
||||
HAL_Bool HAL_GetREVPHClosedLoopControl(HAL_REVPHHandle handle,
|
||||
int32_t* status) {
|
||||
void HAL_SetREVPHClosedLoopControlDisabled(HAL_REVPHHandle handle,
|
||||
int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return false;
|
||||
return;
|
||||
}
|
||||
SimREVPHData[pcm->module].compressorConfigType =
|
||||
HAL_REVPHCompressorConfigType_kDisabled;
|
||||
}
|
||||
|
||||
return SimREVPHData[pcm->module].closedLoopEnabled;
|
||||
void HAL_SetREVPHClosedLoopControlDigital(HAL_REVPHHandle handle,
|
||||
int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return;
|
||||
}
|
||||
SimREVPHData[pcm->module].compressorConfigType =
|
||||
HAL_REVPHCompressorConfigType_kDigital;
|
||||
}
|
||||
|
||||
void HAL_SetREVPHClosedLoopControlAnalog(HAL_REVPHHandle handle,
|
||||
double minAnalogVoltage,
|
||||
double maxAnalogVoltage,
|
||||
int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return;
|
||||
}
|
||||
SimREVPHData[pcm->module].compressorConfigType =
|
||||
HAL_REVPHCompressorConfigType_kAnalog;
|
||||
}
|
||||
|
||||
void HAL_SetREVPHClosedLoopControlHybrid(HAL_REVPHHandle handle,
|
||||
double minAnalogVoltage,
|
||||
double maxAnalogVoltage,
|
||||
int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return;
|
||||
}
|
||||
SimREVPHData[pcm->module].compressorConfigType =
|
||||
HAL_REVPHCompressorConfigType_kHybrid;
|
||||
}
|
||||
|
||||
HAL_REVPHCompressorConfigType HAL_GetREVPHCompressorConfig(
|
||||
HAL_REVPHHandle handle, int32_t* status) {
|
||||
auto pcm = pcmHandles->Get(handle);
|
||||
if (pcm == nullptr) {
|
||||
*status = HAL_HANDLE_ERROR;
|
||||
return HAL_REVPHCompressorConfigType_kDisabled;
|
||||
}
|
||||
return SimREVPHData[pcm->module].compressorConfigType;
|
||||
}
|
||||
|
||||
HAL_Bool HAL_GetREVPHPressureSwitch(HAL_REVPHHandle handle, int32_t* status) {
|
||||
|
||||
@@ -21,7 +21,7 @@ void REVPHData::ResetData() {
|
||||
}
|
||||
initialized.Reset(false);
|
||||
compressorOn.Reset(false);
|
||||
closedLoopEnabled.Reset(true);
|
||||
compressorConfigType.Reset(HAL_REVPHCompressorConfigType_kDisabled);
|
||||
pressureSwitch.Reset(false);
|
||||
compressorCurrent.Reset(0.0);
|
||||
}
|
||||
@@ -39,7 +39,8 @@ HAL_SIMDATAVALUE_DEFINE_CAPI_CHANNEL(HAL_Bool, HALSIM, REVPHSolenoidOutput,
|
||||
SimREVPHData, solenoidOutput)
|
||||
DEFINE_CAPI(HAL_Bool, Initialized, initialized)
|
||||
DEFINE_CAPI(HAL_Bool, CompressorOn, compressorOn)
|
||||
DEFINE_CAPI(HAL_Bool, ClosedLoopEnabled, closedLoopEnabled)
|
||||
DEFINE_CAPI(HAL_REVPHCompressorConfigType, CompressorConfigType,
|
||||
compressorConfigType)
|
||||
DEFINE_CAPI(HAL_Bool, PressureSwitch, pressureSwitch)
|
||||
DEFINE_CAPI(double, CompressorCurrent, compressorCurrent)
|
||||
|
||||
@@ -69,7 +70,7 @@ void HALSIM_RegisterREVPHAllNonSolenoidCallbacks(int32_t index,
|
||||
HAL_Bool initialNotify) {
|
||||
REGISTER(initialized);
|
||||
REGISTER(compressorOn);
|
||||
REGISTER(closedLoopEnabled);
|
||||
REGISTER(compressorConfigType);
|
||||
REGISTER(pressureSwitch);
|
||||
REGISTER(compressorCurrent);
|
||||
}
|
||||
|
||||
@@ -13,7 +13,7 @@ class REVPHData {
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(Initialized)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(SolenoidOutput)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(CompressorOn)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(ClosedLoopEnabled)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(CompressorConfigType)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(PressureSwitch)
|
||||
HAL_SIMDATAVALUE_DEFINE_NAME(CompressorCurrent)
|
||||
|
||||
@@ -22,6 +22,11 @@ class REVPHData {
|
||||
return false;
|
||||
}
|
||||
|
||||
static inline HAL_Value MakeCompressorConfigTypeValue(
|
||||
HAL_REVPHCompressorConfigType value) {
|
||||
return HAL_MakeEnum(value);
|
||||
}
|
||||
|
||||
public:
|
||||
SimDataValue<HAL_Bool, HAL_MakeBoolean, GetInitializedName> initialized{
|
||||
false};
|
||||
@@ -30,8 +35,10 @@ class REVPHData {
|
||||
solenoidOutput[kNumREVPHChannels];
|
||||
SimDataValue<HAL_Bool, HAL_MakeBoolean, GetCompressorOnName> compressorOn{
|
||||
false};
|
||||
SimDataValue<HAL_Bool, HAL_MakeBoolean, GetClosedLoopEnabledName>
|
||||
closedLoopEnabled{true};
|
||||
SimDataValue<HAL_REVPHCompressorConfigType, MakeCompressorConfigTypeValue,
|
||||
GetCompressorConfigTypeName>
|
||||
compressorConfigType{HAL_REVPHCompressorConfigType::
|
||||
HAL_REVPHCompressorConfigType_kDisabled};
|
||||
SimDataValue<HAL_Bool, HAL_MakeBoolean, GetPressureSwitchName> pressureSwitch{
|
||||
false};
|
||||
SimDataValue<double, HAL_MakeDouble, GetCompressorCurrentName>
|
||||
|
||||
Reference in New Issue