mirror of
https://github.com/wpilibsuite/allwpilib
synced 2026-06-20 00:51:42 +00:00
[wpilib] Rewrite DutyCycleEncoder and AnalogEncoder (#6398)
This commit is contained in:
@@ -3,17 +3,36 @@
|
||||
// the WPILib BSD license file in the root directory of this project.
|
||||
|
||||
#include <frc/DutyCycleEncoder.h>
|
||||
#include <frc/MathUtil.h>
|
||||
#include <frc/TimedRobot.h>
|
||||
#include <frc/smartdashboard/SmartDashboard.h>
|
||||
|
||||
constexpr double fullRange = 1.3;
|
||||
constexpr double expectedZero = 0.0;
|
||||
|
||||
class Robot : public frc::TimedRobot {
|
||||
// Duty cycle encoder on channel 0
|
||||
frc::DutyCycleEncoder m_dutyCycleEncoder{0};
|
||||
// 2nd parameter is the range of values. This sensor will output between
|
||||
// 0 and the passed in value.
|
||||
// 3rd parameter is the the physical value where you want "0" to be. How
|
||||
// to measure this is fairly easy. Set the value to 0, place the mechanism
|
||||
// where you want "0" to be, and observe the value on the dashboard, That
|
||||
// is the value to enter for the 3rd parameter.
|
||||
frc::DutyCycleEncoder m_dutyCycleEncoder{0, fullRange, expectedZero};
|
||||
|
||||
public:
|
||||
void RobotInit() override {
|
||||
// Set to 0.5 units per rotation
|
||||
m_dutyCycleEncoder.SetDistancePerRotation(0.5);
|
||||
// If you know the frequency of your sensor, uncomment the following
|
||||
// method, and set the method to the frequency of your sensor.
|
||||
// This will result in more stable readings from the sensor.
|
||||
// Do note that occasionally the datasheet cannot be trusted
|
||||
// and you should measure this value. You can do so with either
|
||||
// an oscilloscope, or by observing the "Frequency" output
|
||||
// on the dashboard while running this sample. If you find
|
||||
// the value jumping between the 2 values, enter halfway between
|
||||
// those values. This number doesn't have to be perfect,
|
||||
// just having a fairly close value will make the output readings
|
||||
// much more stable.
|
||||
m_dutyCycleEncoder.SetAssumedFrequency(967.8_Hz);
|
||||
}
|
||||
|
||||
void RobotPeriodic() override {
|
||||
@@ -26,13 +45,24 @@ class Robot : public frc::TimedRobot {
|
||||
// Output of encoder
|
||||
auto output = m_dutyCycleEncoder.Get();
|
||||
|
||||
// Output scaled by DistancePerPulse
|
||||
auto distance = m_dutyCycleEncoder.GetDistance();
|
||||
// By default, the output will wrap around to the full range value
|
||||
// when the sensor goes below 0. However, for moving mechanisms this
|
||||
// is not usually ideal, as if 0 is set to a hard stop, its still
|
||||
// possible for the sensor to move slightly past. If this happens
|
||||
// The sensor will assume its now at the furthest away position,
|
||||
// which control algorithms might not handle correctly. Therefore
|
||||
// it can be a good idea to slightly shift the output so the sensor
|
||||
// can go a bit negative before wrapping. Usually 10% or so is fine.
|
||||
// This does not change where "0" is, so no calibration numbers need
|
||||
// to be changed.
|
||||
double percentOfRange = fullRange * 0.1;
|
||||
double shiftedOutput = frc::InputModulus(output, 0 - percentOfRange,
|
||||
fullRange - percentOfRange);
|
||||
|
||||
frc::SmartDashboard::PutBoolean("Connected", connected);
|
||||
frc::SmartDashboard::PutNumber("Frequency", frequency);
|
||||
frc::SmartDashboard::PutNumber("Output", output.value());
|
||||
frc::SmartDashboard::PutNumber("Distance", distance);
|
||||
frc::SmartDashboard::PutNumber("Output", output);
|
||||
frc::SmartDashboard::PutNumber("ShiftedOutput", shiftedOutput);
|
||||
}
|
||||
};
|
||||
|
||||
|
||||
Reference in New Issue