/* Copyright (c) FIRST 2014-2016. All Rights Reserved. */
|
|
/* Open Source Software - may be modified and shared by FRC teams. The code */
|
|
/* must be accompanied by the FIRST BSD license file in the root directory of */
|
|
/* the project. */
|
|
/*----------------------------------------------------------------------------*/
|
|
|
|
#include "Compressor.h"
|
|
|
|
#include "HAL/HAL.h"
|
|
#include "WPIErrors.h"
|
|
|
|
/**
|
|
* Constructor.
|
|
*
|
|
* @param module The PCM ID to use (0-62)
|
|
*/
|
|
Compressor::Compressor(uint8_t pcmID) : m_module(pcmID) {
|
|
int32_t status = 0;
|
|
m_compressorHandle = HAL_InitializeCompressor(m_module, &status);
|
|
if (status != 0) {
|
|
wpi_setErrorWithContext(status, HAL_GetErrorMessage(status));
|
|
return;
|
|
}
|
|
SetClosedLoopControl(true);
|
|
}
|
|
|
|
/**
|
|
* Starts closed-loop control. Note that closed loop control is enabled by
|
|
* default.
|
|
*/
|
|
void Compressor::Start() {
|
|
if (StatusIsFatal()) return;
|
|
SetClosedLoopControl(true);
|
|
}
|
|
|
|
/**
|
|
* Stops closed-loop control. Note that closed loop control is enabled by
|
|
* default.
|
|
*/
|
|
void Compressor::Stop() {
|
|
if (StatusIsFatal()) return;
|
|
SetClosedLoopControl(false);
|
|
}
|
|
|
|
/**
|
|
* Check if compressor output is active.
|
|
*
|
|
* @return true if the compressor is on
|
|
*/
|
|
bool Compressor::Enabled() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressor(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Check if the pressure switch is triggered.
|
|
*
|
|
* @return true if pressure is low
|
|
*/
|
|
bool Compressor::GetPressureSwitchValue() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorPressureSwitch(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query how much current the compressor is drawing.
|
|
*
|
|
* @return The current through the compressor, in amps
|
|
*/
|
|
float Compressor::GetCompressorCurrent() const {
|
|
if (StatusIsFatal()) return 0;
|
|
int32_t status = 0;
|
|
float value;
|
|
|
|
value = HAL_GetCompressorCurrent(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Enables or disables automatically turning the compressor on when the
|
|
* pressure is low.
|
|
*
|
|
* @param on Set to true to enable closed loop control of the compressor. False
|
|
* to disable.
|
|
*/
|
|
void Compressor::SetClosedLoopControl(bool on) {
|
|
if (StatusIsFatal()) return;
|
|
int32_t status = 0;
|
|
|
|
HAL_SetCompressorClosedLoopControl(m_compressorHandle, on, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
}
|
|
|
|
/**
|
|
* Returns true if the compressor will automatically turn on when the
|
|
* pressure is low.
|
|
*
|
|
* @return True if closed loop control of the compressor is enabled. False if
|
|
* disabled.
|
|
*/
|
|
bool Compressor::GetClosedLoopControl() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorClosedLoopControl(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output has been disabled due to high current draw.
|
|
*
|
|
* @return true if PCM is in fault state : Compressor Drive is
|
|
* disabled due to compressor current being too high.
|
|
*/
|
|
bool Compressor::GetCompressorCurrentTooHighFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorCurrentTooHighFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output has been disabled due to high current draw
|
|
* (sticky).
|
|
*
|
|
* A sticky fault will not clear on device reboot, it must be cleared through
|
|
* code or the webdash.
|
|
*
|
|
* @return true if PCM sticky fault is set : Compressor Drive is
|
|
* disabled due to compressor current being too high.
|
|
*/
|
|
bool Compressor::GetCompressorCurrentTooHighStickyFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value =
|
|
HAL_GetCompressorCurrentTooHighStickyFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output has been disabled due to a short circuit
|
|
* (sticky).
|
|
*
|
|
* A sticky fault will not clear on device reboot, it must be cleared through
|
|
* code or the webdash.
|
|
*
|
|
* @return true if PCM sticky fault is set : Compressor output
|
|
* appears to be shorted.
|
|
*/
|
|
bool Compressor::GetCompressorShortedStickyFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorShortedStickyFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output has been disabled due to a short circuit.
|
|
*
|
|
* @return true if PCM is in fault state : Compressor output
|
|
* appears to be shorted.
|
|
*/
|
|
bool Compressor::GetCompressorShortedFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorShortedFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output does not appear to be wired (sticky).
|
|
*
|
|
* A sticky fault will not clear on device reboot, it must be cleared through
|
|
* code or the webdash.
|
|
*
|
|
* @return true if PCM sticky fault is set : Compressor does not
|
|
* appear to be wired, i.e. compressor is not drawing enough current.
|
|
*/
|
|
bool Compressor::GetCompressorNotConnectedStickyFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorNotConnectedStickyFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Query if the compressor output does not appear to be wired.
|
|
*
|
|
* @return true if PCM is in fault state : Compressor does not
|
|
* appear to be wired, i.e. compressor is not drawing enough current.
|
|
*/
|
|
bool Compressor::GetCompressorNotConnectedFault() const {
|
|
if (StatusIsFatal()) return false;
|
|
int32_t status = 0;
|
|
bool value;
|
|
|
|
value = HAL_GetCompressorNotConnectedFault(m_compressorHandle, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
|
|
return value;
|
|
}
|
|
|
|
/**
|
|
* Clear ALL sticky faults inside PCM that Compressor is wired to.
|
|
*
|
|
* If a sticky fault is set, then it will be persistently cleared. Compressor
|
|
* drive maybe momentarily disable while flags are being cleared. Care should
|
|
* be taken to not call this too frequently, otherwise normal compressor
|
|
* functionality may be prevented.
|
|
*
|
|
* If no sticky faults are set then this call will have no effect.
|
|
*/
|
|
void Compressor::ClearAllPCMStickyFaults() {
|
|
if (StatusIsFatal()) return;
|
|
int32_t status = 0;
|
|
|
|
HAL_ClearAllPCMStickyFaults(m_module, &status);
|
|
|
|
if (status) {
|
|
wpi_setWPIError(Timeout);
|
|
}
|
|
}
|
|
|
|
void Compressor::UpdateTable() {
|
|
if (m_table) {
|
|
m_table->PutBoolean("Enabled", Enabled());
|
|
m_table->PutBoolean("Pressure switch", GetPressureSwitchValue());
|
|
}
|
|
}
|
|
|
|
void Compressor::StartLiveWindowMode() {}
|
|
|
|
void Compressor::StopLiveWindowMode() {}
|
|
|
|
std::string Compressor::GetSmartDashboardType() const { return "Compressor"; }
|
|
|
|
void Compressor::InitTable(std::shared_ptr<ITable> subTable) {
|
|
m_table = subTable;
|
|
UpdateTable();
|
|
}
|
|
|
|
std::shared_ptr<ITable> Compressor::GetTable() const { return m_table; }
|
|
|
|
void Compressor::ValueChanged(ITable* source, llvm::StringRef key,
|
|
std::shared_ptr<nt::Value> value, bool isNew) {
|
|
if (!value->IsBoolean()) return;
|
|
if (value->GetBoolean())
|
|
Start();
|
|
else
|
|
Stop();
|
|
}
|