mirror of
https://github.com/wpilibsuite/allwpilib
synced 2026-06-23 01:21:42 +00:00
* ErrorBase: Use magic static singleton for globals * ErrorBase: Add testability features for global errors * Make WPIError definitions inline functions (This works around cross-DLL variable issues on Windows) Fixes #1726.
96 lines
4.9 KiB
C++
96 lines
4.9 KiB
C++
/*----------------------------------------------------------------------------*/
|
|
/* Copyright (c) 2008-2019 FIRST. All Rights Reserved. */
|
|
/* Open Source Software - may be modified and shared by FRC teams. The code */
|
|
/* must be accompanied by the FIRST BSD license file in the root directory of */
|
|
/* the project. */
|
|
/*----------------------------------------------------------------------------*/
|
|
|
|
#pragma once
|
|
|
|
#include <stdint.h>
|
|
|
|
#define S(label, offset, message) \
|
|
constexpr inline const char* wpi_error_s_##label() { return message; } \
|
|
constexpr inline int wpi_error_value_##label() { return offset; }
|
|
|
|
// Fatal errors
|
|
S(ModuleIndexOutOfRange, -1,
|
|
"Allocating module that is out of range or not found")
|
|
S(ChannelIndexOutOfRange, -1, "Allocating channel that is out of range")
|
|
S(NotAllocated, -2, "Attempting to free unallocated resource")
|
|
S(ResourceAlreadyAllocated, -3, "Attempted to reuse an allocated resource")
|
|
S(NoAvailableResources, -4, "No available resources to allocate")
|
|
S(NullParameter, -5, "A pointer parameter to a method is nullptr")
|
|
S(Timeout, -6, "A timeout has been exceeded")
|
|
S(CompassManufacturerError, -7, "Compass manufacturer doesn't match HiTechnic")
|
|
S(CompassTypeError, -8,
|
|
"Compass type doesn't match expected type for HiTechnic compass")
|
|
S(IncompatibleMode, -9, "The object is in an incompatible mode")
|
|
S(AnalogTriggerLimitOrderError, -10,
|
|
"AnalogTrigger limits error. Lower limit > Upper Limit")
|
|
S(AnalogTriggerPulseOutputError, -11,
|
|
"Attempted to read AnalogTrigger pulse output.")
|
|
S(TaskError, -12, "Task can't be started")
|
|
S(TaskIDError, -13, "Task error: Invalid ID.")
|
|
S(TaskDeletedError, -14, "Task error: Task already deleted.")
|
|
S(TaskOptionsError, -15, "Task error: Invalid options.")
|
|
S(TaskMemoryError, -16, "Task can't be started due to insufficient memory.")
|
|
S(TaskPriorityError, -17, "Task error: Invalid priority [1-255].")
|
|
S(DriveUninitialized, -18, "RobotDrive not initialized for the C interface")
|
|
S(CompressorNonMatching, -19,
|
|
"Compressor slot/channel doesn't match previous instance")
|
|
S(CompressorAlreadyDefined, -20, "Creating a second compressor instance")
|
|
S(CompressorUndefined, -21,
|
|
"Using compressor functions without defining compressor")
|
|
S(InconsistentArrayValueAdded, -22,
|
|
"When packing data into an array to the dashboard, not all values added were "
|
|
"of the same type.")
|
|
S(MismatchedComplexTypeClose, -23,
|
|
"When packing data to the dashboard, a Close for a complex type was called "
|
|
"without a matching Open.")
|
|
S(DashboardDataOverflow, -24,
|
|
"When packing data to the dashboard, too much data was packed and the buffer "
|
|
"overflowed.")
|
|
S(DashboardDataCollision, -25,
|
|
"The same buffer was used for packing data and for printing.")
|
|
S(EnhancedIOMissing, -26, "IO is not attached or Enhanced IO is not enabled.")
|
|
S(LineNotOutput, -27,
|
|
"Cannot SetDigitalOutput for a line not configured for output.")
|
|
S(ParameterOutOfRange, -28, "A parameter is out of range.")
|
|
S(SPIClockRateTooLow, -29, "SPI clock rate was below the minimum supported")
|
|
S(JaguarVersionError, -30, "Jaguar firmware version error")
|
|
S(JaguarMessageNotFound, -31, "Jaguar message not found")
|
|
S(NetworkTablesReadError, -40, "Error reading NetworkTables socket")
|
|
S(NetworkTablesBufferFull, -41, "Buffer full writing to NetworkTables socket")
|
|
S(NetworkTablesWrongType, -42,
|
|
"The wrong type was read from the NetworkTables entry")
|
|
S(NetworkTablesCorrupt, -43, "NetworkTables data stream is corrupt")
|
|
S(SmartDashboardMissingKey, -43, "SmartDashboard data does not exist")
|
|
S(CommandIllegalUse, -50, "Illegal use of Command")
|
|
S(UnsupportedInSimulation, -80, "Unsupported in simulation")
|
|
S(CameraServerError, -90, "CameraServer error")
|
|
S(InvalidParameter, -100, "Invalid parameter value")
|
|
|
|
// Warnings
|
|
S(SampleRateTooHigh, 1, "Analog module sample rate is too high")
|
|
S(VoltageOutOfRange, 2,
|
|
"Voltage to convert to raw value is out of range [-10; 10]")
|
|
S(CompressorTaskError, 3, "Compressor task won't start")
|
|
S(LoopTimingError, 4, "Digital module loop timing is not the expected value")
|
|
S(NonBinaryDigitalValue, 5, "Digital output value is not 0 or 1")
|
|
S(IncorrectBatteryChannel, 6,
|
|
"Battery measurement channel is not correct value")
|
|
S(BadJoystickIndex, 7, "Joystick index is out of range, should be 0-3")
|
|
S(BadJoystickAxis, 8, "Joystick axis or POV is out of range")
|
|
S(InvalidMotorIndex, 9, "Motor index is out of range, should be 0-3")
|
|
S(DriverStationTaskError, 10, "Driver Station task won't start")
|
|
S(EnhancedIOPWMPeriodOutOfRange, 11,
|
|
"Driver Station Enhanced IO PWM Output period out of range.")
|
|
S(SPIWriteNoMOSI, 12, "Cannot write to SPI port with no MOSI output")
|
|
S(SPIReadNoMISO, 13, "Cannot read from SPI port with no MISO input")
|
|
S(SPIReadNoData, 14, "No data available to read from SPI")
|
|
S(IncompatibleState, 15,
|
|
"Incompatible State: The operation cannot be completed")
|
|
|
|
#undef S
|