// Copyright (c) FIRST and other WPILib contributors.
// Open Source Software; you can modify and/or share it under the terms of
// the WPILib BSD license file in the root directory of this project.
#include "Robot.hpp"
#include "wpi/smartdashboard/SmartDashboard.hpp"
#include "wpi/units/pressure.hpp"
Robot::Robot() {
// Publish elements to shuffleboard.
frc::SmartDashboard::PutData("Single Solenoid", &m_solenoid);
frc::SmartDashboard::PutData("Double Solenoid", &m_doubleSolenoid);
frc::SmartDashboard::PutData("Compressor", &m_compressor);
}
void Robot::TeleopPeriodic() {
// Publish some raw data
// Get the pressure (in PSI) from the analog sensor connected to the PH.
// This function is supported only on the PH!
// On a PCM, this function will return 0.
frc::SmartDashboard::PutNumber("PH Pressure [PSI]",
m_compressor.GetPressure().value());
// Get compressor current draw.
frc::SmartDashboard::PutNumber("Compressor Current",
m_compressor.GetCurrent().value());
// Get whether the compressor is active.
frc::SmartDashboard::PutBoolean("Compressor Active",
m_compressor.IsEnabled());
// Get the digital pressure switch connected to the PCM/PH.
// The switch is open when the pressure is over ~120 PSI.
frc::SmartDashboard::PutBoolean("Pressure Switch",
m_compressor.GetPressureSwitchValue());
/*
* The output of GetRawButton is true/false depending on whether
* the button is pressed; Set takes a boolean for whether
* to retract the solenoid (false) or extend it (true).
*/
m_solenoid.Set(m_stick.GetRawButton(kSolenoidButton));
/*
* GetRawButtonPressed will only return true once per press.
* If a button is pressed, set the solenoid to the respective channel.
*/
if (m_stick.GetRawButtonPressed(kDoubleSolenoidForward)) {
m_doubleSolenoid.Set(frc::DoubleSolenoid::kForward);
} else if (m_stick.GetRawButtonPressed(kDoubleSolenoidReverse)) {
m_doubleSolenoid.Set(frc::DoubleSolenoid::kReverse);
}
// On button press, toggle the compressor with the mode selected from the
// dashboard.
if (m_stick.GetRawButtonPressed(kCompressorButton)) {
// Check whether the compressor is currently enabled.
bool isCompressorEnabled = m_compressor.IsEnabled();
if (isCompressorEnabled) {
// Disable closed-loop mode on the compressor.
m_compressor.Disable();
} else {
// Change the if directives to select the closed-loop mode you want to
// use:
#if 0
// Enable closed-loop mode based on the digital pressure switch
// connected to the PCM/PH.
m_compressor.EnableDigital();
#endif
#if 1
// Enable closed-loop mode based on the analog pressure sensor connected
// to the PH. The compressor will run while the pressure reported by the
// sensor is in the specified range ([70 PSI, 120 PSI] in this example).
// Analog mode exists only on the PH! On the PCM, this enables digital
// control.
m_compressor.EnableAnalog(70_psi, 120_psi);
#endif
#if 0
// Enable closed-loop mode based on both the digital pressure switch AND the analog
// pressure sensor connected to the PH.
// The compressor will run while the pressure reported by the analog sensor is in the
// specified range ([70 PSI, 120 PSI] in this example) AND the digital switch reports
// that the system is not full.
// Hybrid mode exists only on the PH! On the PCM, this enables digital control.
m_compressor.EnableHybrid(70_psi, 120_psi);
#endif
}
}
}
#ifndef RUNNING_FRC_TESTS
int main() {
return frc::StartRobot<Robot>();
}
#endif