// Copyright (c) FIRST and other WPILib contributors.
|
|
// Open Source Software; you can modify and/or share it under the terms of
|
|
// the WPILib BSD license file in the root directory of this project.
|
|
|
|
#include "Robot.hpp"
|
|
|
|
#include "wpi/smartdashboard/SmartDashboard.hpp"
|
|
#include "wpi/units/pressure.hpp"
|
|
|
|
Robot::Robot() {
|
|
// Publish elements to shuffleboard.
|
|
frc::SmartDashboard::PutData("Single Solenoid", &m_solenoid);
|
|
frc::SmartDashboard::PutData("Double Solenoid", &m_doubleSolenoid);
|
|
frc::SmartDashboard::PutData("Compressor", &m_compressor);
|
|
}
|
|
|
|
void Robot::TeleopPeriodic() {
|
|
// Publish some raw data
|
|
|
|
// Get the pressure (in PSI) from the analog sensor connected to the PH.
|
|
// This function is supported only on the PH!
|
|
// On a PCM, this function will return 0.
|
|
frc::SmartDashboard::PutNumber("PH Pressure [PSI]",
|
|
m_compressor.GetPressure().value());
|
|
// Get compressor current draw.
|
|
frc::SmartDashboard::PutNumber("Compressor Current",
|
|
m_compressor.GetCurrent().value());
|
|
// Get whether the compressor is active.
|
|
frc::SmartDashboard::PutBoolean("Compressor Active",
|
|
m_compressor.IsEnabled());
|
|
// Get the digital pressure switch connected to the PCM/PH.
|
|
// The switch is open when the pressure is over ~120 PSI.
|
|
frc::SmartDashboard::PutBoolean("Pressure Switch",
|
|
m_compressor.GetPressureSwitchValue());
|
|
|
|
/*
|
|
* The output of GetRawButton is true/false depending on whether
|
|
* the button is pressed; Set takes a boolean for whether
|
|
* to retract the solenoid (false) or extend it (true).
|
|
*/
|
|
m_solenoid.Set(m_stick.GetRawButton(kSolenoidButton));
|
|
|
|
/*
|
|
* GetRawButtonPressed will only return true once per press.
|
|
* If a button is pressed, set the solenoid to the respective channel.
|
|
*/
|
|
if (m_stick.GetRawButtonPressed(kDoubleSolenoidForward)) {
|
|
m_doubleSolenoid.Set(frc::DoubleSolenoid::kForward);
|
|
} else if (m_stick.GetRawButtonPressed(kDoubleSolenoidReverse)) {
|
|
m_doubleSolenoid.Set(frc::DoubleSolenoid::kReverse);
|
|
}
|
|
|
|
// On button press, toggle the compressor with the mode selected from the
|
|
// dashboard.
|
|
if (m_stick.GetRawButtonPressed(kCompressorButton)) {
|
|
// Check whether the compressor is currently enabled.
|
|
bool isCompressorEnabled = m_compressor.IsEnabled();
|
|
if (isCompressorEnabled) {
|
|
// Disable closed-loop mode on the compressor.
|
|
m_compressor.Disable();
|
|
} else {
|
|
// Change the if directives to select the closed-loop mode you want to
|
|
// use:
|
|
#if 0
|
|
// Enable closed-loop mode based on the digital pressure switch
|
|
// connected to the PCM/PH.
|
|
m_compressor.EnableDigital();
|
|
#endif
|
|
#if 1
|
|
// Enable closed-loop mode based on the analog pressure sensor connected
|
|
// to the PH. The compressor will run while the pressure reported by the
|
|
// sensor is in the specified range ([70 PSI, 120 PSI] in this example).
|
|
// Analog mode exists only on the PH! On the PCM, this enables digital
|
|
// control.
|
|
m_compressor.EnableAnalog(70_psi, 120_psi);
|
|
#endif
|
|
#if 0
|
|
// Enable closed-loop mode based on both the digital pressure switch AND the analog
|
|
// pressure sensor connected to the PH.
|
|
// The compressor will run while the pressure reported by the analog sensor is in the
|
|
// specified range ([70 PSI, 120 PSI] in this example) AND the digital switch reports
|
|
// that the system is not full.
|
|
// Hybrid mode exists only on the PH! On the PCM, this enables digital control.
|
|
m_compressor.EnableHybrid(70_psi, 120_psi);
|
|
#endif
|
|
}
|
|
}
|
|
}
|
|
|
|
#ifndef RUNNING_FRC_TESTS
|
|
int main() {
|
|
return frc::StartRobot<Robot>();
|
|
}
|
|
#endif
|