// Copyright (c) FIRST and other WPILib contributors.
// Open Source Software; you can modify and/or share it under the terms of
// the WPILib BSD license file in the root directory of this project.
#pragma once
#include <memory>
#include <hal/Types.h>
#include <wpi/sendable/Sendable.h>
#include <wpi/sendable/SendableHelper.h>
#include "frc/CompressorConfigType.h"
#include "frc/PneumaticsBase.h"
#include "frc/PneumaticsModuleType.h"
#include "frc/SensorUtil.h"
namespace frc {
/**
* Class for operating a compressor connected to a pneumatics module.
*
* The module will automatically run in closed loop mode by default whenever a
* Solenoid object is created. For most cases, a Compressor object does not need
* to be instantiated or used in a robot program. This class is only required in
* cases where the robot program needs a more detailed status of the compressor
* or to enable/disable closed loop control.
*
* Note: you cannot operate the compressor directly from this class as doing so
* would circumvent the safety provided by using the pressure switch and closed
* loop control. You can only turn off closed loop control, thereby stopping
* the compressor from operating.
*/
class Compressor : public wpi::Sendable,
public wpi::SendableHelper<Compressor> {
public:
/**
* Constructs a compressor for a specified module and type.
*
* @param busId The bus ID.
* @param module The module ID to use.
* @param moduleType The module type to use.
*/
Compressor(int busId, int module, PneumaticsModuleType moduleType);
/**
* Constructs a compressor for a default module and specified type.
*
* @param busId The bus ID.
* @param moduleType The module type to use.
*/
Compressor(int busId, PneumaticsModuleType moduleType);
~Compressor() override;
Compressor(const Compressor&) = delete;
Compressor& operator=(const Compressor&) = delete;
Compressor(Compressor&&) = default;
Compressor& operator=(Compressor&&) = default;
/**
* Returns whether the compressor is active or not.
*
* @return true if the compressor is on - otherwise false.
*/
bool IsEnabled() const;
/**
* Returns the state of the pressure switch.
*
* @return True if pressure switch indicates that the system is not full,
* otherwise false.
*/
bool GetPressureSwitchValue() const;
/**
* Get the current drawn by the compressor.
*
* @return Current drawn by the compressor.
*/
units::ampere_t GetCurrent() const;
/**
* If supported by the device, returns the analog input voltage (on channel
* 0).
*
* This function is only supported by the REV PH. On CTRE PCM, this will
* return 0.
*
* @return The analog input voltage, in volts.
*/
units::volt_t GetAnalogVoltage() const;
/**
* If supported by the device, returns the pressure read by the analog
* pressure sensor (on channel 0).
*
* This function is only supported by the REV PH with the REV Analog Pressure
* Sensor. On CTRE PCM, this will return 0.
*
* @return The pressure read by the analog pressure sensor.
*/
units::pounds_per_square_inch_t GetPressure() const;
/**
* Disable the compressor.
*/
void Disable();
/**
* Enables the compressor in digital mode using the digital pressure switch.
* The compressor will turn on when the pressure switch indicates that the
* system is not full, and will turn off when the pressure switch indicates
* that the system is full.
*/
void EnableDigital();
/**
* If supported by the device, enables the compressor in analog mode. This
* mode uses an analog pressure sensor connected to analog channel 0 to cycle
* the compressor. The compressor will turn on when the pressure drops below
* {@code minPressure} and will turn off when the pressure reaches {@code
* maxPressure}. This mode is only supported by the REV PH with the REV Analog
* Pressure Sensor connected to analog channel 0.
*
* On CTRE PCM, this will enable digital control.
*
* @param minPressure The minimum pressure. The compressor will turn on when
* the pressure drops below this value.
* @param maxPressure The maximum pressure. The compressor will turn off when
* the pressure reaches this value.
*/
void EnableAnalog(units::pounds_per_square_inch_t minPressure,
units::pounds_per_square_inch_t maxPressure);
/**
* If supported by the device, enables the compressor in hybrid mode. This
* mode uses both a digital pressure switch and an analog pressure sensor
* connected to analog channel 0 to cycle the compressor. This mode is only
* supported by the REV PH with the REV Analog Pressure Sensor connected to
* analog channel 0.
*
* The compressor will turn on when \a both:
*
* - The digital pressure switch indicates the system is not full AND
* - The analog pressure sensor indicates that the pressure in the system
* is below the specified minimum pressure.
*
* The compressor will turn off when \a either:
*
* - The digital pressure switch is disconnected or indicates that the system
* is full OR
* - The pressure detected by the analog sensor is greater than the specified
* maximum pressure.
*
* On CTRE PCM, this will enable digital control.
*
* @param minPressure The minimum pressure. The compressor will turn on
* when the pressure drops below this value and the pressure switch indicates
* that the system is not full.
* @param maxPressure The maximum pressure. The compressor will turn
* off when the pressure reaches this value or the pressure switch is
* disconnected or indicates that the system is full.
*/
void EnableHybrid(units::pounds_per_square_inch_t minPressure,
units::pounds_per_square_inch_t maxPressure);
/**
* Returns the active compressor configuration.
*
* @return The active compressor configuration.
*/
CompressorConfigType GetConfigType() const;
void InitSendable(wpi::SendableBuilder& builder) override;
private:
std::shared_ptr<PneumaticsBase> m_module;
PneumaticsModuleType m_moduleType;
};