mirror of
https://github.com/wpilibsuite/allwpilib
synced 2026-06-19 00:41:43 +00:00
77 lines
4.6 KiB
C
77 lines
4.6 KiB
C
/*----------------------------------------------------------------------------*/
|
|
/* Copyright (c) FIRST 2008. All Rights Reserved. */
|
|
/* Open Source Software - may be modified and shared by FRC teams. The code */
|
|
/* must be accompanied by the FIRST BSD license file in $(WIND_BASE)/WPILib. */
|
|
/*----------------------------------------------------------------------------*/
|
|
#pragma once
|
|
|
|
#ifdef WPI_ERRORS_DEFINE_STRINGS
|
|
#define S(label, offset, message) const char *wpi_error_s_##label = message ;
|
|
#else
|
|
#define S(label, offset, message) extern const char *wpi_error_s_##label;
|
|
#endif
|
|
|
|
/*
|
|
* Fatal errors
|
|
*/
|
|
S(ModuleIndexOutOfRange, -1, "Allocating module that is out of range or not found");
|
|
S(ChannelIndexOutOfRange, -1, "Allocating channel that is out of range");
|
|
S(NotAllocated, -2, "Attempting to free unallocated resource");
|
|
S(ResourceAlreadyAllocated, -3, "Attempted to reuse an allocated resource");
|
|
S(NoAvailableResources, -4, "No available resources to allocate");
|
|
S(NullParameter, -5, "A pointer parameter to a method is NULL");
|
|
S(Timeout, -6, "A timeout has been exceeded");
|
|
S(CompassManufacturerError, -7, "Compass manufacturer doesn't match HiTechnic");
|
|
S(CompassTypeError, -8, "Compass type doesn't match expected type for HiTechnic compass");
|
|
S(IncompatibleMode, -9, "The object is in an incompatible mode");
|
|
S(AnalogTriggerLimitOrderError, -10, "AnalogTrigger limits error. Lower limit > Upper Limit");
|
|
S(AnalogTriggerPulseOutputError, -11, "Attempted to read AnalogTrigger pulse output.");
|
|
S(TaskError, -12, "Task can't be started");
|
|
S(TaskIDError, -13, "Task error: Invalid ID.");
|
|
S(TaskDeletedError, -14, "Task error: Task already deleted.");
|
|
S(TaskOptionsError, -15, "Task error: Invalid options.");
|
|
S(TaskMemoryError, -16, "Task can't be started due to insufficient memory.");
|
|
S(TaskPriorityError, -17, "Task error: Invalid priority [1-255].");
|
|
S(DriveUninitialized, -18, "RobotDrive not initialized for the C interface");
|
|
S(CompressorNonMatching, -19, "Compressor slot/channel doesn't match previous instance");
|
|
S(CompressorAlreadyDefined, -20, "Creating a second compressor instance");
|
|
S(CompressorUndefined, -21, "Using compressor functions without defining compressor");
|
|
S(InconsistentArrayValueAdded, -22, "When packing data into an array to the dashboard, not all values added were of the same type.");
|
|
S(MismatchedComplexTypeClose, -23, "When packing data to the dashboard, a Close for a complex type was called without a matching Open.");
|
|
S(DashboardDataOverflow, -24, "When packing data to the dashboard, too much data was packed and the buffer overflowed.");
|
|
S(DashboardDataCollision, -25, "The same buffer was used for packing data and for printing.");
|
|
S(EnhancedIOMissing, -26, "IO is not attached or Enhanced IO is not enabled.");
|
|
S(LineNotOutput, -27, "Cannot SetDigitalOutput for a line not configured for output.");
|
|
S(ParameterOutOfRange, -28, "A parameter is out of range.");
|
|
S(SPIClockRateTooLow, -29, "SPI clock rate was below the minimum supported");
|
|
S(JaguarVersionError, -30, "Jaguar firmware version error");
|
|
S(JaguarMessageNotFound, -31, "Jaguar message not found");
|
|
S(NetworkTablesReadError, -40, "Error reading NetworkTables socket");
|
|
S(NetworkTablesBufferFull, -41, "Buffer full writing to NetworkTables socket");
|
|
S(NetworkTablesWrongType, -42, "The wrong type was read from the NetworkTables entry");
|
|
S(NetworkTablesCorrupt, -43, "NetworkTables data stream is corrupt");
|
|
S(SmartDashboardMissingKey, -43, "SmartDashboard data does not exist");
|
|
S(CommandIllegalUse, -50, "Illegal use of Command");
|
|
S(UnsupportedInSimulation, -80, "Unsupported in simulation");
|
|
|
|
/*
|
|
* Warnings
|
|
*/
|
|
S(SampleRateTooHigh, 1, "Analog module sample rate is too high");
|
|
S(VoltageOutOfRange, 2, "Voltage to convert to raw value is out of range [-10; 10]");
|
|
S(CompressorTaskError, 3, "Compressor task won't start");
|
|
S(LoopTimingError, 4, "Digital module loop timing is not the expected value");
|
|
S(NonBinaryDigitalValue, 5, "Digital output value is not 0 or 1");
|
|
S(IncorrectBatteryChannel, 6, "Battery measurement channel is not correct value");
|
|
S(BadJoystickIndex, 7, "Joystick index is out of range, should be 1-4");
|
|
S(BadJoystickAxis, 8, "Joystick axis is out of range");
|
|
S(InvalidMotorIndex, 9, "Motor index is out of range, should be 0-3");
|
|
S(DriverStationTaskError, 10, "Driver Station task won't start");
|
|
S(EnhancedIOPWMPeriodOutOfRange, 11, "Driver Station Enhanced IO PWM Output period out of range.");
|
|
S(SPIWriteNoMOSI, 12, "Cannot write to SPI port with no MOSI output");
|
|
S(SPIReadNoMISO, 13, "Cannot read from SPI port with no MISO input");
|
|
S(SPIReadNoData, 14, "No data available to read from SPI");
|
|
S(IncompatibleState, 15, "Incompatible State: The operation cannot be completed");
|
|
|
|
#undef S
|